Our competition

Our ADMS structure gives the opportunity to be optimized for different boundary conditions. The lattice structure also needed to be chosen wisely. Two load cases were chosen for the comparison: compression (homogeneous) and shear (unhomogeneous).

Fundamental to fair testing was to have similar weight and wall thickness (0.4mm). The testing was based on composite core material testing norms: DIN EN ISO 844 for compression, DIN EN 12090 for shear. The samples were printed by the same supplier, the tests were performed by a composite testing facility in Berlin.

Shear test

The results shown a superior performance for ADMS structures. They can be explained with the ideal stress distribution in the structure and the better connection to the solid faces. As a lattice structure connects point by point, the ADMS unites through lines for the solid interface.

Compression test

The results shown a superior performance for ADMS structures. They can be explained with the ideal stress distribution in the structure and the better connection to the solid faces. As a lattice structure connects point by point, the ADMS unites through lines for the solid interface.

  • "The spherene technology introduces a completely new way of thinking about how components can be designed and laid out, which has been lacking until now."

    Matthias Blaser